Threshold gas detectors DG/EF
New
New
Cost-effective threshold detectors of toxic and combustible gases (also oxygen and refrigerants) with splash-proof construction
The DG/EF two-threshold, economical detectors are designed to detect the presence of dangerous gas concentrations in the air in industrial, enclosed spaces. They have a replaceable sensor module with two standard alarm thresholds (thresholds set at the production stage, built-in third threshold signaled only optically).
DG/EF detectors are designed to work with:
- threshold control units of type MD-1.A/T, MD-1, MD-2, MD-4;
- measuring and threshold control units of type MDP-1.A/T, MDP-1 PLUS, MDP-4, MDP-8, MDP-16.
DG/EF are detectors of standard design and cannot be used in areas classified as hazardous due to the presence of gases, vapors, or dust.
Features
- replaceable gas sensor: semiconductor, optical (Infra-Red);
- two alarm thresholds set during production (the third threshold is usually the upper measurement range of the gas sensor, signaled only visually), 4-wire interface;
- built-in event history (analysis available from the manufacturer), indication of the recommended calibration period expiry; built-in test procedure for recognizing output cables (after power-up);
- thermal compensation system (can be used in variable environmental conditions);
- easy gas penetration through the sensor cover = relatively short detector response time;
- built-in optical signaling (multi-color LED);
- removable terminals with the possibility of mounting single- and multi-wire cores (cable – without crimping sleeves);
- splash-proof IP44 gas sensor cover (in the recommended mounting position);
- can be equipped with a mechanical cover made of AR-1 profiled pipes (installation in areas exposed to mechanical damage, e.g., warehouses, wholesale stores, parking lots);
- all detectors are calibrated in our own GAZEX Calibration Laboratory operating in accordance with the PN-EN ISO/IEC 17025 standard (PCA accreditation no. AP150).
Offered models
| Model | Gas sensor module | Sensor | Substance/property | Standard alarm thresholds or measuring range | Supply voltage | Net price | C.g. | ||
|---|---|---|---|---|---|---|---|---|---|
| DG-14/EF | New | MS-14/N | Semiconductor |
Methane (CH4) |
10/30/(40) |
%LEL |
System powered | PLN569.00 | S |
| DG-15/EF | New | MS-15/N | Semiconductor |
Liquefied petroleum gas (LPG) |
10/30/(40) |
%LEL |
System powered | PLN569.00 | S |
| DG-22/EF | New | MS-22/NL | Semiconductor |
Carbon monoxide (CO) |
(TWA/STEL) 20/100/(300) |
ppm |
System powered | PLN569.00 | S |
| DG-8R8/EF | New | MS-8R8/N | Infra-red |
Carbon dioxide (CO2) |
0,5/1,5/(2) |
%v/v |
System powered | PLN699.00 | S |
| Model | Gas sensor module | Sensor | Substance/property | Standard alarm thresholds or measuring range | Supply voltage | Contact control outputs | Voltage control outputs 12VDC | Two-state outputs (threshold) | Control output "Fault" | Output controlling the shut-off valve | Output in 4-20mA standard | Output in 0-10V standard | Output in 2-10V standard | Output in RS-485 standard | Visual signalling, built-in | Acoustic signaling, built-in | Internal battery | Dimensions | Net price | C.g. | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DG-14/EF | New | MS-14/N | Semiconductor |
Methane (CH4) |
10/30/(40) |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | ✓ | — | — | 110 x 153 x 60 mm | PLN569.00 | S |
| DG-15/EF | New | MS-15/N | Semiconductor |
Liquefied petroleum gas (LPG) |
10/30/(40) |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | ✓ | — | — | 110 x 153 x 60 mm | PLN569.00 | S |
| DG-22/EF | New | MS-22/NL | Semiconductor |
Carbon monoxide (CO) |
(TWA/STEL) 20/100/(300) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | ✓ | — | — | 110 x 153 x 60 mm | PLN569.00 | S |
| DG-8R8/EF | New | MS-8R8/N | Infra-red |
Carbon dioxide (CO2) |
0,5/1,5/(2) |
%v/v |
System powered | — | — | 2 | — | — | — | — | — | — | ✓ | — | — | 110 x 153 x 60 mm | PLN699.00 | S |
Suggested products
Splash-proof enclosures AP-1
Tubular shields AR-1
Gas test sets GTS