Threshold gas detectors DG/A

DG/A two-threshold detectors are designed to detect the presence of dangerous concentrations of explosive or toxic gases or vapors in the air in industrial, enclosed spaces. They feature a replaceable sensor module with two alarm thresholds (thresholds set at the production stage, with a built-in third threshold that is usually the upper recommended measurement range).

DG/A detectors have a passive 4-20 mA, 3-wire interface and are designed to work with MDP alarm modules or other control modules that accept devices with a passive (current-absorbing) output.

DG/A detectors are of standard design and cannot be used in areas classified as hazardous due to the presence of gases, vapors, or dust.

Features

  • replaceable, intelligent semiconductor gas sensor;
  • two alarm thresholds set at the production stage (the third threshold is usually the upper measurement range of the gas sensor, signaled only optically), 4-20 mA passive, 3-wire interface;
  • built-in event history (analysis available from the manufacturer), indication of the recommended calibration period; built-in test procedure to recognize output cables (after power-up);
  • thermal compensation system (can be used in variable environmental conditions);
  • easy gas penetration through the sensor cover = relatively short detector response time;
  • built-in optical signaling (multi-color LED);
  • removable terminals with the possibility of mounting single and multi-wire cores (cable - without crimping sleeves);
  • splash-proof IP44 gas sensor cover (in the recommended mounting position);
  • can be equipped with a mechanical cover made of AR-1 profiled pipes (installation in areas exposed to mechanical damage, e.g., warehouses, wholesale stores, parking lots);
  • can be equipped with a housing for installation on a ventilation duct (version DG/w);
  • all detectors are calibrated in GAZEX Calibration Laboratory operating in accordance with the PN-EN ISO/IEC 17025 standard (PCA accreditation no. AP150).

Offered models

Model Gas sensor module Sensor Substance/property Standard alarm thresholds Measuring range UoM Supply voltage
New MS-12/N Semiconductor Methane (CH4)
10/30/(40)
5—40
%LEL
System powered
New MS-14/N Semiconductor Methane (CH4)
10/30/(40)
5—40
%LEL
System powered
New MS-15/N Semiconductor Liquefied petroleum gas (LPG)
10/30/(40)
5—40
%LEL
System powered
New MS-22/NL Semiconductor Carbon monoxide (CO)
20/100/(200)
20—1000
ppm
System powered
New MS-31/N Semiconductor Organic compounds
20/40/(50)
5—40
%LEL
System powered
New MS-41/N Semiconductor Ammonia (NH3)
500/1500/(2000)
300—5000
ppm
System powered
New MS-61/N Semiconductor R32
or R410A
1000/2000/(2500)
500—3000
ppm
System powered
New MS-71/N Semiconductor Acetylene (C2H2)
or Hydrogen (H2)
10/30/(40)
5—40
%LEL
System powered
New MS-73/N Semiconductor Hydrogen (H2)
10/30/(40)
5—40
%LEL
System powered
Model Gas sensor module Sensor Substance/property Standard alarm thresholds Measuring range UoM Supply voltage Contact control outputs Voltage control outputs 12VDC Two-state outputs (threshold) Control output "Fault" Output controlling the shut-off valve Visual signalling, built-in Acoustic signaling, built-in Internal battery Dimensions Price excl. VAT Price inc. VAT C.g.
New MS-12/N Semiconductor Methane (CH4)
10/30/(40)
5—40
%LEL
System powered 2 110 x 153 x 60 mm PLN769.00 PLN945.87 N
New MS-14/N Semiconductor Methane (CH4)
10/30/(40)
5—40
%LEL
System powered 2 110 x 153 x 60 mm PLN769.00 PLN945.87 N
New MS-15/N Semiconductor Liquefied petroleum gas (LPG)
10/30/(40)
5—40
%LEL
System powered 2 110 x 153 x 60 mm PLN769.00 PLN945.87 N
New MS-22/NL Semiconductor Carbon monoxide (CO)
20/100/(200)
20—1000
ppm
System powered 2 110 x 153 x 60 mm F
New MS-31/N Semiconductor Organic compounds
20/40/(50)
5—40
%LEL
System powered 2 110 x 153 x 60 mm F
New MS-41/N Semiconductor Ammonia (NH3)
500/1500/(2000)
300—5000
ppm
System powered 2 110 x 153 x 60 mm F
New MS-61/N Semiconductor R32
or R410A
1000/2000/(2500)
500—3000
ppm
System powered 2 110 x 153 x 60 mm F
New MS-71/N Semiconductor Acetylene (C2H2)
or Hydrogen (H2)
10/30/(40)
5—40
%LEL
System powered 2 110 x 153 x 60 mm F
New MS-73/N Semiconductor Hydrogen (H2)
10/30/(40)
5—40
%LEL
System powered 2 110 x 153 x 60 mm F

Suggested products

Splash-proof enclosures to protect detectors from adverse weather conditions and mechanical damage
Profiled tube guards to protect the detector from direct mechanical damage
Test sets for verifying the correct operation of detectors by injecting a gaseous test mixture into the measuring chamber of the detector