Optical (infra-red), measuring sensor modules MS-PnR/N
Electronic components of measuring detectors, equipped with an optical gas sensor
MS sensor modules contain the gas sensor and all the necessary electronic components for their calibration.
If calibration is necessary, the user can remove the sensor module and send it for calibration, and replace it with another one already calibrated. These operations are carried out without having to dismantle the detector from the installation. This unique technical solution makes the operation of gas detection systems much easier and cheaper.
Sensor modules are equipped with a microprocessor and log the sensor’s operating parameters such as: number of alarms, operating time in alarm states, the number of overruns of measuring ranges and possible emergency states. During calibration, it is possible to trace the conditions in which the detectors work and, if necessary, make corrections in the settings of operating parameters of the systems, or propose a change of sensors to other, more suitable for specific conditions in the monitored object. In the case of a change of plant conditions and/or hazardous substances, there is no need to replace the detection system - it is enough to replace the sensor modules with those suitable for the new conditions, which is a simpler, quicker and more cost-effective solution.
Offered models
Model | Sensor | Substance/property | Standard alarm thresholds or measuring range | Net price | C.g. | Calibration net price | C.g. | ||
---|---|---|---|---|---|---|---|---|---|
MS-P1R2/N | Infra-red |
Methane (CH4) |
0 ÷ 100 |
%LEL |
PLN1,400.00 | C | PLN119.00 | C | |
MS-P1R5/N | Infra-red |
Liquefied petroleum gas (LPG) |
0 ÷ 100 |
%LEL |
PLN1,400.00 | C | PLN119.00 | C | |
MS-P3R/N | Infra-red |
Organic compounds |
0 ÷ 100 |
%LEL |
PLN1,500.00 | CN | PLN179.00 | C | |
MS-P3R/N-X | Infra-red |
Organic compounds |
0 ÷ 100 |
%LEL |
PLN1,500.00 | CN | PLN179.00 | C | |
MS-P6R7/N | Infra-red |
Hydrofluorocarbon (R32) or Hydrofluorocarbon (R410A) |
0 ÷ 2000 |
ppm |
PLN2,600.00 | CN | PLN179.00 | C | |
MS-P6R7/N-SF6 | Infra-red |
Sulfur hexafluoride (SF6) |
0 ÷ 2000 |
ppm |
PLN2,600.00 | CN | PLN179.00 | C | |
MS-P8R/N | Infra-red |
Carbon dioxide (CO2) |
0 ÷ 5 |
%v/v |
PLN1,400.00 | C | PLN119.00 | C | |
MS-P8R8.EG | Infra-red |
Carbon dioxide (CO2) |
0 ÷ 2 |
%v/v |
CN | C | |||
MS-P8R8/N | Infra-red |
Carbon dioxide (CO2) |
0 ÷ 2 |
%v/v |
PLN900.00 | C | PLN119.00 | C |
Model | In the detector | Sensor | Substance/property | Standard alarm thresholds or measuring range | Net price | C.g. | Calibration net price | C.g. | ||
---|---|---|---|---|---|---|---|---|---|---|
MS-P1R2/N |
DEX-P1R2/N
DG-P1R2/N DG-PV1R2 DG-P1R2/M DG-P1R2/MR |
Infra-red |
Methane (CH4) |
0 ÷ 100 |
%LEL |
PLN1,400.00 | C | PLN119.00 | C | |
MS-P1R5/N |
DEX-P1R5/N
DG-P1R5/N DG-PV1R5 DG-P1R5/M DG-P1R5/MR |
Infra-red |
Liquefied petroleum gas (LPG) |
0 ÷ 100 |
%LEL |
PLN1,400.00 | C | PLN119.00 | C | |
MS-P3R/N |
DG-P3R/N
DG-PV3R DG-P3R/M DG-P3R/MR |
Infra-red |
Organic compounds |
0 ÷ 100 |
%LEL |
PLN1,500.00 | CN | PLN179.00 | C | |
MS-P3R/N-X | DEX-P3R/N | Infra-red |
Organic compounds |
0 ÷ 100 |
%LEL |
PLN1,500.00 | CN | PLN179.00 | C | |
MS-P6R7/N |
DG-P6R7/N
DG-PV6R7 DG-P6R7/M DG-P6R7/MR |
Infra-red |
Hydrofluorocarbon (R32) or Hydrofluorocarbon (R410A) |
0 ÷ 2000 |
ppm |
PLN2,600.00 | CN | PLN179.00 | C | |
MS-P6R7/N-SF6 |
DG-P6R7/N-SF6
DG-PV6R7-SF6 DG-P6R7/M-SF6 DG-P6R7/MR-SF6 |
Infra-red |
Sulfur hexafluoride (SF6) |
0 ÷ 2000 |
ppm |
PLN2,600.00 | CN | PLN179.00 | C | |
MS-P8R/N |
DEX-P8R/N
DG-P8R/N DG-PV8R DG-P8R/M DG-P8R/MR AirTECH max+ AirTECH max+/420 AirTECH max+/M AirTECH max+/V10 |
Infra-red |
Carbon dioxide (CO2) |
0 ÷ 5 |
%v/v |
PLN1,400.00 | C | PLN119.00 | C | |
MS-P8R8.EG | DG-P8R8.EN | Infra-red |
Carbon dioxide (CO2) |
0 ÷ 2 |
%v/v |
CN | C | |||
MS-P8R8/N |
DG-P8R8/N
DG-PV8R8 DG-P8R8/M DG-P8R8/MR |
Infra-red |
Carbon dioxide (CO2) |
0 ÷ 2 |
%v/v |
PLN900.00 | C | PLN119.00 | C |