DG-PV0E.HCL
                    
                        
                        
                        
                        
                        
                        
                        
                    
                
            Type of device: DG/PV Description of device type
DG/PV are designed to measure and monitor dangerous concentrations of toxic and explosive gases (and oxygen) in the air in enclosed industrial spaces. They have an interchangeable module with a measuring sensor.
They are designed to cooperate with control units (systems) of various manufacturers requiring detectors with active current output 4-20 mA or voltage output 2-10 V.
DG/PV detectors have a standard casing and cannot be used in areas classified as explosive gas, vapor or dust zones.
(Note: DG/PV detectors are not intended for use with MDP, MDA or MDD type modules).
Features
- interchangeable gas sensor;
 - 2 outputs: current in standard 4-20 mA (active, i.e. emitting current) and voltage 2-10 V;
 - built-in signaling of exceeding the measuring and temperature range, operating time counter, history of emergency states and signalling the end of calibration;
 - thermal compensation system (can be used under changing environmental conditions);
 - short detector response time;
 - built-in optical signalling (2 LED lights);
 - removable terminals with the possibility of embedding single and multi wire conductors (without crimping the sleeves);
 - splash-proof gas sensor cover IP44 (in recommended mounting position);
 - additional mechanical shield made of profiled tubes available - type AR-1d (installation in zones exposed to mechanical damage, e.g. warehouses, wholesalers, parking lots);
 - possibility of being equipped with an enclosure to be placed on a ventilation duct (option DG/w);
 - sensor modules for DG/PV and DG/P are interchangeable (different modules can be used for the same DG/PV body) – however, the installation conditions for individual gas must be taken into account;
 - all detectors are calibrated in our own GAZEX Calibration Laboratory operating in accordance with PN-EN ISO/IEC 17025 (PCA accreditation No AP150).
 
Block diagram

Device model: DG-PV0E.HCL
Technical parameters
- Output in 4-20mA standard
 - ✓
 - Output in 2-10V standard
 - ✓
 - Visual signalling, built-in
 - ✓
 - Supply voltage
 - 24 V DC
 - Dimensions
 - 110 x 140 x 55 mm
 - Net price
 - PLN1,949.00 N
 
| Gas sensor module | Sensor | Substance/property | Standard alarm thresholds or measuring range | |
|---|---|---|---|---|
| MS-P0E.HCL/N | Electrochemical | 
                    
                    Hydrogen chloride (HCl) | 
                 0 ÷ 30 | 
                ppm | 
            
Documentation
| Series | Technical data | User Manual | Declaration of conformity | |
|---|---|---|---|---|
| W2 | Download file | — | Download file | |
| Archived series | ||||
| W1 | Download file | — | Download file | |