DG/F
Threshold detectors of toxic and combustible gases (also oxygen and Freon HFC) with splash-proof construction
Comparison table
Model | Type | Gas sensor module | Sensor | Substance/property | Standard alarm thresholds or measuring range | Supply voltage | Contact control outputs | Voltage control outputs 12VDC | Two-state outputs (threshold) | Control output "Fault" | Output controlling the shut-off valve | Output in 4-20mA standard | Output in 0-10V standard | Output in 2-10V standard | Output in RS-485 standard | Visual signalling, built-in | Acoustic signaling, built-in | Internal battery | Dimensions (W x H x D) | Net price | C/G | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DG-12/N | DG/F | MS-12/N | Semiconductor |
Methane (CH4) |
10/30 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 659.00 zł | S | ||
DG-14/N | DG/F | MS-14/N | Semiconductor |
Methane (CH4) |
10/30 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 659.00 zł | S | ||
DG-15/N | DG/F | MS-15/N | Semiconductor |
Liquefied petroleum gas (LPG) |
10/30 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 659.00 zł | S | ||
DG-22/NL | DG/F | MS-22/NL | Semiconductor |
Carbon monoxide (CO) |
20/100 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 659.00 zł | N | ||
DG-31/N | DG/F | MS-31/N | Semiconductor |
Organic compounds |
20/40 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 739.00 zł | N | ||
DG-41/N | DG/F | MS-41/N | Semiconductor |
Ammonia (NH3) |
500/1500 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 699.00 zł | N | ||
DG-61/N | DG/F | MS-61/N | Semiconductor |
Hydrofluorocarbons (HFC) |
1000/2000 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 699.00 zł | N | ||
DG-71/N | DG/F | MS-71/N | Semiconductor |
Acetylene (C2H2) or Hydrogen (H2) |
10/30 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 699.00 zł | N | ||
DG-72/N | DG/F | MS-72/N | Semiconductor |
Hydrogen (H2) |
20/40 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 659.00 zł | S | ||
DG-TF | DG/F | MS-TF | Semiconductor |
Temperature (T) |
– |
°C |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 469.00 zł | N | ||
DG-0E.ASH3/N | DG/F | MS-0E.ASH3/N | Electrochemical |
Arsine (AsH3) |
0,2/0,4 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.B2H6/N | DG/F | MS-0E.B2H6/N | Electrochemical |
Diborane (B2H6) |
0,2/0,4 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.CL2/N | DG/F | MS-0E.CL2/N | Electrochemical |
Chlorine (Cl2) |
1/3 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.CLO2/N | DG/F | MS-0E.CLO2/N | Electrochemical |
Chlorine dioxide (ClO2) |
0,1/0,3 (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.COCL2/N | DG/F | MS-0E.COCL2/N | Electrochemical |
Phosgene (COCl2) |
0,2/0,4 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.ETO/N | DG/F | MS-0E.ETO/N | Electrochemical |
Ethylene oxide (C2H4O) |
2/5 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.HCL/N | DG/F | MS-0E.HCL/N | Electrochemical |
Hydrogen chloride (HCl) |
3,3/6,6 (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.HCN/N | DG/F | MS-0E.HCN/N | Electrochemical |
Hydrogen cyanide (HCN) |
3/6 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.NO2/N | DG/F | MS-0E.NO2/N | Electrochemical |
Nitrogen dioxide (NO2) |
1/3 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.NO/N | DG/F | MS-0E.NO/N | Electrochemical |
Nitrogen monoxide (NO) |
2/– (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.O3/N | DG/F | MS-0E.O3/N | Electrochemical |
Ozone (O3) |
0,2/0,3 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.PH3/N | DG/F | MS-0E.PH3/N | Electrochemical |
Hydrogen phosphide (PH3) |
0,1/0,2 (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.SEH2/N | DG/F | MS-0E.SEH2/N | Electrochemical |
Hydrogen selenide (H2Se) |
1/3 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.SIH4/N | DG/F | MS-0E.SIH4/N | Electrochemical |
Silane (SiH4) |
5/10 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-0E.SO2/N | DG/F | MS-0E.SO2/N | Electrochemical |
Sulfur dioxide (SO2) |
0.5/1 (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | N | |||
DG-2E/N | DG/F | MS-2E/N | Electrochemical |
Carbon monoxide (CO) |
20/100 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 899.00 zł | N | ||
DG-4E/N | DG/F | MS-4E/N | Electrochemical |
Ammonia (NH3) |
500/800 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 999.00 zł | N | ||
DG-4E/N1 | DG/F | MS-4E/N1 | Electrochemical |
Ammonia (NH3) |
20/40 (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 999.00 zł | N | ||
DG-4E/N2 | DG/F | MS-4E/N2 | Electrochemical |
Ammonia (NH3) |
20/40 (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 1,199.00 zł | N | ||
DG-5E/N | DG/F | MS-5E/N | Electrochemical |
Hydrogen sulfide (H2S) |
5/10 (TWA/STEL) |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 899.00 zł | N | ||
DG-7E/N | DG/F | MS-7E/N | Electrochemical |
Hydrogen (H2) |
500/800 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 999.00 zł | N | ||
DG-9E/4 | DG/F | MS-9E/4 | Electrochemical |
Oxygen (O2) |
19/18 |
%v/v |
System powered | — | — | — | — | — | — | — | — | — | — | — | 110 x 185 x 55 mm | 699.00 zł | S | ||
DG-9E/N | DG/F | MS-9E/N | Electrochemical |
Oxygen (O2) |
19/18 |
%v/v |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 849.00 zł | S | ||
DG-9E/4-1 | DG/F | MS-9E/4-1 | Electrochemical |
Oxygen (O2) |
19/18 |
%v/v |
System powered | — | — | — | — | — | — | — | — | — | — | — | 110 x 185 x 55 mm | 699.00 zł | S | ||
DG-1R2/N | DG/F | MS-1R2/N | Infra-red |
Methane (CH4) |
10/30 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 1,599.00 zł | S | ||
DG-1R5/N | DG/F | MS-1R5/N | Infra-red |
Liquefied petroleum gas (LPG) |
10/30 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 1,599.00 zł | S | ||
DG-3R/N | DG/F | MS-3R/N | Infra-red |
Organic compounds |
20/40 |
%LEL |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 1,739.00 zł | N | ||
DG-6R7/N | DG/F | MS-6R7/N | Infra-red |
Hydrofluorocarbons (HFC) |
500/1500 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 2,899.00 zł | N | ||
DG-6R7/N-SF6 | DG/F | MS-6R7/N-SF6 | Infra-red |
Sulfur hexafluoride (SF6) |
500/1500 |
ppm |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 2,899.00 zł | N | ||
DG-8R8/N | DG/F | MS-8R8/N | Infra-red |
Carbon dioxide (CO2) |
0,5/1,5 |
%v/v |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 1,099.00 zł | S | ||
DG-8R/N | DG/F | MS-8R/N | Infra-red |
Carbon dioxide (CO2) |
0,5/1,5 |
%v/v |
System powered | — | — | 2 | — | — | — | — | — | — | — | — | 110 x 140 x 55 mm | 1,599.00 zł | N |
Detection of substance/property in other areas or other substances/properties is possible = special execution, requires consultation.
In special cases, it is possible to select the detector parameters for a specific application = required analysis of the conditions of use.